Error & Warning Messages

Warnings

W001 - this item already exists

Attempt to drop a device or a rack in rack input or rack output of a The Rack, which already has been added. Duplicated items are not allowed.

W002 - nothing to record

Trying to record with the Direct to Disk Panel but this one is empty, so there is nothing to record.

Solution: add on the Direct to Disk Panel at least one Audio in devices, Audio in devices or The Rack.

W003 - clipboard empty

Trying to use the paste command [cmd+v] but with an empty clipboard.

W004 - edition disabled on this control

Trying to [Double click] on a disabled fader or knob.

Solution: set the edit enabled property on

W005 - the object is locked

The object is disabled or locked (edit enabled property off) and cant be modified.

W007 - unable to undo

Impossible to undo with the [cmd+z], probably because the undo history is empty.

W008 - unable to redo

Impossible to redo with the [shift+cmd+z], probably because the redo history is empty.

W009 - nothing selected

Attempt to use a delete command but nothing is selected, so there is nothing to delete…

W010 - a Mixer already exists for this rack

Attempt to drop a The Rack on the The Mixer Panel which already has been added. Duplicated items are not allowed.

W011 - the control is not in a rack

The control can’t be located in a The Rack because it hasn’t a parent rack. Typically because the control is in a The Devices Panel patch.

W012 - the container or popup module doesn't exist

The control can’t be located in a Popup Window or Container because there is no popup or container in the patch (or parent patch).

W013 - patch sharing is not activated in the setup

Attempt to share a patch over the lan without activate the share option in the setup.

W014 - bind out of range

The value assigned to a bind bus must be in the range [0..1].

solution: activate the auto calibration or verify the range before send the value to a bus or deactivate the add to bind list

note: by default buses are added to the bind list.

W015 - OSC learn out of range

The OSC value received and assigned with osc learn is not in the the range [0..1]. Must be in this range when the OSC mode is set to in [0..1]

W016 - this control can''t be recorded

Attempt to record an automation on a control which can’t be recorded for many reasons. Generally because they are read only or in the The Settings Panel.

W017 - not allowed to rename

The current control can’t be renamed with a [alt+click]. Generally because they are read only or in the The Settings Panel.

W018 - scan aborted

The browser search (scan) has been canceled by the user. Typically by pressing a key during the scan procedure.

W019 - invalid path in FileLister module

The path parameter of the File Lister is invalid.

W020 - invalid filename

The module Load Workspace or Load Patch has an invalid filename parameter and can’t be processed.

W021 - ID recreated

After a Recreate ID’s procedure some ID’s have changed and so, some presets can be lost.

W022 - unable to convert script

Conversion error during the importation of an old version Script to the new Fast Script. See Fastscript Compatibility notes for more information.

W023 - artnet DMX is limited to 512 channels

Attempt to send an Artnet DMX value on a channel above the 512 allowed. Values above this limit are ignored.

W024 - the main audio engine is off

The operation is impossible because the main audio engine is off

W025 - no sampler found. Impossible to synchronize

You try to synchronize a curve with a sampler but no sampler is found in the current rack.

W026 - no external editor defined in the setup

You try to edit an audio file but no external editor is defined in the setup.

W027 - multiple in/out flows not allowed on this in/outlet

You try to connect several flow to a visual control in/outlet which is not allowed.

solution:Try to use the “add” module instead.

WSDK100 invalid color number

You try to call the sdkGetUsineColor with an invalid color number argument. A default value is returned.

Errors

E001 - unable to get addonslist

Usine can’t access to the server to get addons list.

  • you’re not connected to Internet
  • the sensomusic server is temporary down

E002 - unable to create temp file

Usine try to create a temporary file in directory /temp without success.

  • the directory is write protected
  • your disk is full
  • your disk is corrupted
  • a conflict occurs with “Dropbox like” applications

E003 - error connecting to

Usine can’t connect to the chat server.

  • you’re not connected to Internet
  • the chat server is temporary down

E004 - unable to convert mp3 file

Conversion process error of file to MP3 format.

E005 - unable to read audio file

For some reasons Usine cant read the content of the audio file.

  • the file is corrupted

E006 - empty file or not in memory

You try to save an empty audio file.

E007 - unable to rename or copy the file

For some reasons it’s impossible to rename or copy the selected file

  • the directory is write protected
  • your disk is full
  • your disk is corrupted
  • a conflict occurs with “Dropbox like” applications

E008 - bad audio file header

The audio file is not valid, in an unsupported format or corrupted.

E009 - out of memory

No more memory available on your computer. Be aware that on 32bits versions Usine shouldn’t be bigger than 3GB in memory.

E010 - audio driver not started, please choose it in the setup

The audio driver has not started or is not selected in the setup/audio.

E011 - file not found

The file you attempt to open is not found in the original location.

E012 - invalid inlets

Usine try to connect wires to unexpected in/outlets.

  • generally a compatibility issue with very old patches.

E013 - unable to paste at this position

Usine can’t paste grid item

  • the destination place is not empty

E014 - unable to export the user module

You try to export a patch which contains invalid or deleted user modules.

E015 - unable to load plugin

Impossible to load the AU or VST plugin

  • not compatible with you system version
  • you try to open a 32bits plug into a Usine 64bits, or inverse
  • the plugin doesn’t exists any more in your system

E016 - a container module already exists in this patch

You can’t add more than one container module in a patch.

E017 - a popup module already exists in this patch

You can’t add more than one popup module in a patch.

E018 - this UserModule isn't compatible with this version of Usine

You try to load an incompatible user module.

  • the user module is probably too old

E019 - send Midi out, device not activated

You try to send MIDI to a device which is not activated in the setup/midi.

E020 - Send Midi SysEx out, device not activated

You try to send SYSEX to a device which is not activated in the setup/midi.

E021 - invalid bar list

The bar list used in the main synchro is not valid.

E022 - get index by order

Internal Messages Language (IML) error. The object not found.

E023 - Usine busy

Internal error, this messages should not appears.

  • Quit and restart Usine.

E024 - invalid format, not 16, 24 or 32 bits

Usine don’t support 8bits or 64bits audio files.

E025 - unable to open audio file

Impossible to open the audio file.

  • access conflict with another application

E026 - invalid midifile format (old version)

You try to open a very old midifile Usine format.

E027 - UDP Sendfile

An error occurs during the transfer of a shared patch. Usine will retry later.

E028 - invalid UDP file transfert

An error occurs during the transfer of a shared patch, the file is corrupted. Usine will retry later.

E029 - additional audio i/o module not allowed in this patch

You try to put an Additional Input or Additional Audio Output in a patch which can’t receive them because it is not in a rack.

  • you patch is a device

E030 - queue overflow in Array Difference module

Error inside the Array Difference module.

  • your array is too big to be handled correctly

E031 - inifile locked

Internal error, this messages should not appears.

  • Quit and restart Usine.

E032 - in call Callback procedure

Internal error, occurs in the messages loop.

E033 - audio dropout

Internal error. The workspace takes too many time to be processed. Something goes wrong.

  • endless loop in a script
  • a AU/VST plugin has crashed
  • a polyphonic patch is to heavy

E034 - artnet server not active

You try to send artnet packets over the lan but artnet is not activated in the setup.

E035 - unable to send Open DMX

The OpenDMX module is not available on your system.

E036 - invalid username, password or optional key

You entered an invalid password or username to activate Usine.

E038 invalid record directory in the setup

You entered an invalid record (Direct to Disk) directory in the setup. Recording aborted.

E039 unable to get battery informations

For an unknown reason the Battery Level module can’t retrieve informations.

E040 error in update joystick procedure

For an unknown reason an error occurs in the Joystick module.

E901 - in process patch

Internal error, appear during the patch calculation.

  • a script crashes
  • your patch is corrupted
  • a plugin (VST, AU) crashes